Laboratory Tests


Test 1

Envirodyne Laboratories, Inc.
Environmental Services

June 4, 2004

Dave Galloway
Aquamaker, LLC
10627 Kinghurst Drive
Houston, Texas 77099

Dear Mr. Galloway:

On May 20, 2004, Envirodyne Laboratories, Inc. (ELI) inoculated a distilled water sample with E.coli and Salmonella. ELI transported the sample to the Aquamaker facility located at 10627 Kinghurst Drive, Houston, Texas. Aquamaker staff filtered the sample and an aliquot was collectdd by ELI.

E.coli and Salmonella testing was conducted on the sample before and after filteration. E.coli result before filteration were 16000 CFU/100 ml and <1 CFU/100ml after filteration. Salmonella results before filteration were 162 CFU/100 ml and <1 CFU/100ml after filteration. (Refer to Sample ID's AA33151 and AA33150)

This letter is to certify that the testing performed by Envirodyne Laboratories. Inc. for E.coli and Salmonella meets all criteria outlined in Standard Methods 18th Edition methods 9222B and 9260B.

Please contact me at 281-568-7880 if any additional information is needed.

Regards,


Test 2

Date Collected : 08/30/04
Date Received :
08/31/04
Date Complited :
09/07/04
Sample Code :
624676

DEALER ADDRESS
AQUAMAKER
10627 KINGHURST DR
HUSTON, TX 77099-

ID: AM10-0412
NOTE : "*" The MCL (Maximum Contaminant Level) or an established
guideline has been exceeded for this contaminant.
"ND" This contaminant was not detected at or above our stated detection level.
"NA" Not Analyzed.

RESULTS

Analysis performed: MCL(mg/l) Detection Level Level Detected
Analysis performed: MCL(mg/l) Detection Level Level Detected
Inorganic chemicals -metals:
Aluminum 0.2 0.1 ND
Arsenic 0.05 0.010 ND
Barium 2 0.30 ND
Cadmium 0.005 0.002 ND
Calcium ---- 2 ND
Chromium 0.1 0.010 ND
Copper 1.3 0.004 ND
Iron 0.3 0.020 ND
Lead 0.015 0.002 ND
Magnesium ---- 0.10 ND
Manganese 0.05 0.004 ND
Mercury 0.002 0.001 ND
Nickel ---- 0.02 ND
Selenium 0.05 0.020 ND
Silver 0.1 0.002 0.011
Sodium ---- 1 10
Zinc 5 0.004 ND
Analysis performed: MCL(mg/l) Detection Level Level Detected
Analysis performed: MCL(mg/l) Detection Level Level Detected
Inorganic chemicals -other, and physical factors:
Alkalinity (Total as CaCO3) ---- 20 22
Chloride 250 5.0 ND
Fluoride 4 0.5 ND
Hardness (suggested limit = 100)   10 ND
Nitrate as N 10 0.5 ND
Nitrite as N 1 0.5 ND
pH (Standard Units) 6.5-8.5 ---- 7.2
Sulfate 250 5.0 ND
Total Dissolved Solids 500 20 23
Turbidity (Turbidity Units) 1.0 0.1 0.3

** These test results are intended to be used for informational purposes only and may not be used for regulatory compliance.

James C. Bahen
Laboratory Director, National Testing Laboratories